The Netlinx NX integrated controller is designed to be command central for local AV and building control. ...Read more

AMX NX-4200 NetLinx NX Integrated Controller Image 1
AMX NX-4200 NetLinx NX Integrated Controller Image 2
AMX NX-4200 NetLinx NX Integrated Controller Image 3
AMX NX-4200 NetLinx NX Integrated Controller Image 4
AMX NX-4200 NetLinx NX Integrated Controller
Our Price: $5,500.00

SPECIAL FINANCING AVAILABLE

Synchrony Music & Sound Card
$153/mo* with 36 month financing. ‡
Limited Time. Learn How
Item usually available to ship in 5-9 Business Days. Please call for up-to-date information on product availability.

Questions? Contact our
Sales and Service Pros for expert
advice and package pricing.

800-356-5844

Email customer service

Product Overview

The Netlinx NX integrated controller is designed to be command central for local AV and building control. This programmable network appliance supports using multiple analog and digital formats combining backward compatibility with its forward-looking technology.

The NX-4200 boasts NX Master Security firmware and dual NIC (Network Interface Cards) and other security features that make it ideal for enterprise, education, and government applications requiring secure communication over a computer network. The unit also features redundant power capabilities and can be powered via AC mains or an external 12V DC power supply.

Primarily designed for commercial and government use, the NX-4200 is right at home when being used for residential applications. Integrated PoE (Power over Ethernet) allows you to power other PoE devices over a secure, isolated network. The controller also supports the NX Series of Integrated Controllers, including projectors, lighting, DVD and Blu-ray players, thermostats, and other electronic equipment.

AMX NX-4200 Includes:

  • NX-4200 with 2 removable rack ears

AMX NX-4200 Features:

  • Front Panel Display – Features an LCD display on the front panel, making it easy to view status information, network settings, IP addresses & ICSLan Port status, among others
  • Redundant Power Source – The NX-4200 can be powered either with a connection to mains AC power (110/220VAC) or from an external 12V DC power supply. If the AC input power is lost or if the internal power supply fails, the NX-4200 will immediately switch to the 12V DC power input without interruption except to PoE devices on the ICSLan
  • Dual NIC with Power – Enables two discrete network interfaces for unrivaled security and includes a 4 Port switch with PoE allowing you to power PoE devices over a secure, isolated network. The LAN port is used to connect the master to an external network, and the ICSLAN ports connect to AMX or third-party A/V equipment isolated from the primary network
  • IPv6 – Supports Internet Protocol version 6 (IPv6), the communications protocol that provides an identification and location system for computers on networks and routes traffic across the Internet
  • IEEE 802.1X – Supports IEEE Standard for Port-based Network Access Control with the ability to grant or deny network access to devices wishing to attach to a LAN based on credentials tied to the device rather than to a user
  • X.509 Certificate Services – NX supports customer-provided certificates for access to protected networks
  • Full LDAP Integration – Supports multiple user-defined login groups for accessing the master, as well as provides an AMX programmer the capability to require network login to access certain areas of the touch panel
  • High Performance Architecture, Flexible Programming Platform (RPM, NetLinx and Java) – Easily scalable to support a wide range of applications for today and tomorrow
  • Full Line Compatible (Backwards and Cross-Compatibility) – Standardized port numbers and new configuration import/export tools mean fewer coding changes
  • TLS / SSH Client – Provides NetLinx programmers the ability to manage secure port TLS and SSH communications with a remote device or server
  • Cryptographic Support – In accordance with FIPS 140-2, a U.S. government computer security standard used to accredit cryptographic modules for the protection of sensitive or valuable data
  • Network Syslog – Supports standard device logging to a syslog server
  • Enhanced Diagnostics On Serial and IR Ports – Provides real-time error feedback when Serial and IR ports are disconnected or improperly wired
  • File Import / Export From USB Drive – Backup and restore configuration data, program files, and update firmware from a standard USB flash drive
  • Ultra-Fast 1600 MIPS processor

AMX NX-4200 Specifications:

  • Dimensions (HxWxD): 1.8” x 17.0” x 9.1” (45.15 x 431.80 x 231.64 mm)
  • Weight: 7.6 lbs (3.447 Kg)
  • Memory: Memory Card: 8 GB SD, NVRAM: 1 MB, DDRAM: 1 GB, Note: Supports external USB Solid State Drives
  • Power Consumption: Active Power Consumption: 8.4 W
  • AxLink Port: (2) 4-position 3.5mm Screw Terminal, provides data and power to external AxLink control devices
  • AxLink Indicator: (2) AxLink LED (green) indicates the state of the AxLink port
  • RS-232/422/485 Ports: (2) 10-position 3.5mm Screw Terminal, NetLinx Port 1 and 5, XON/XOFF (transmit on / transmit off), CTS/RTS (clear to send/ready to send), 300 - 115,200 baud
  • RS-232 Port: (6) 5-position 3.5mm Screw Terminal, NetLinx Ports 2-4 and 6-8, XON/XOFF (transmit on / transmit off), CTS/RTS (clear to send/ready to send), 300 - 115,200 baud
  • Serial Indicator: (8) sets of LEDs (red/yellow) indicate when serial Ports 1 - 8 are transmitting and receiving data
  • IR/Serial: (8) 2-position 3.5mm Screw Terminal, 8 IR Transmit / 1-way Serial ports, NetLinx Ports 11-18, Support high-frequency carriers up to 1.142 MHz, 8 IR/Serial data signals can be generated simultaneously
  • IR/Serial Indicators: (2) LEDs (red) indicate when each of the IR/Serial ports (11-18) are transmitting control data
  • I/O Channels: (8) One 10-position 3.5mm Screw Terminal, 8-channel binary I/O port for contact closure with each input being capable of voltage sensing, NetLinx Port 22, Channels 1-8
  • I/O Indicator: (8) LEDs (yellow) indicate each of the I/O channels (1-8) are active
  • Relays: (8) Two 8-position 3.5 mm Screw Terminal, (8) single-pole, single-throw relays, NetLinx Port 21, Channels 1-8, Each relay can switch up to 24 VDC or 28 VAC @ 1 A, Each relay is independently controlled
  • Relay Indicators: (8) LEDs (red) indicate when each of the relay channels (1-8) are active (closed)