Product Overview

Introducing the 5700ACO Automatic Changeovers – the ultimate solution for TV station video and time synchronization. Designed for two 5700MSC Master Clock/Sync Generators, it ensures reliability and minimal disruption with mechanical relays, even during power failures. Featuring 2RU ACO, dual power supplies, and enhanced security with switches for manual and automatic modes. LEDs provide status info, while VistaLINK® allows customizable autochangeover features. Simplified installation with GPI/GPO connections. Experience unparalleled security and efficiency with the 5700ACO Automatic Changeovers.

Evertz 5700ACO Features:

  • Three protected switches select automatic, front panel or GPI activation of changeover
  • Front panel status LEDs show the health of each of the inputs
  • Front panel status LEDs show the operational modes of the changeover
  • Redundant power supply standard
  • Push button to show cause of last changeover
  • Dual hot–swappable power supplied and fans
  • Hot–swappable main board
  • GPIO input/outputs
  • Automatic changeover is a voting system based on which source has the most valid signals and that the valid signals on the present master are also on the backup
  • VistaLINK® control for device configuration and status monitoring
  • Six video/sync or other coaxial signals
  • 10MHz frequency reference
  • Word clock output
  • DARS and 3 AES
  • Two Longitudinal (LTC/EBU) timecode outputs
  • Four SD/HD/3G outputs

Evertz 5700ACO Specifications:

  • LTC/IRIG Inputs and Outputs:
    • Standard: SMPTE ST 12–1 frame rate set
    • by 5700MSC or IRIG–B
    • Inputs: 2 per 5700MSC
    • Outputs: 2
  • Connectors:
    • Inputs: Female DB15
    • Outputs: 3–pin male XLR type
    • Signal Level: Set in 5700MSC
    • Coaxial Inputs and Outputs:
    • Type: Depends on signal connected
      • from 5700MSC
    • HD–SDI, SD–SDI, Analog TG, AES,
    • DARS, bi–level or tri–level sync,
    • colour black, 10MHz, Word Clock
    • Number: 12 groups each consisting of two inputs and one output
    • Connector: BNC per IEC 61169–8 Annex A
  • ACO General Purpose Inputs and Output:
    • Inputs:
      • GPI1: Master select in
      • Manual GPI control mode
      • Low: Selects Master A
      • High: Selects Master B
      • GPI2: Dual GPO mode.
      • GPI 1 Low, GPI 2 High
        • selects Master A
      • GPI 1 High, GPI Low
      • selects Master B
      • Otherwise no change
    • Outputs:
    • GPO1: Low: Master A is selected
    • High: Master B is selected
    • GPO2: Low: Master A and Master B
    • differ or PSU failure
    • High: Master A and B have
    • equivalent signals
  • Type:
    • Inputs: Opto–isolated input with internal
      • pull–up to +5V
    • Outputs: Normally closed relay to ground
      • 10kW internal pull–up to +5V when relay is in active position
    • Connector: 4 pins plus 2 ground pins on 12–pin removable terminal block
    • Signal Level: +5V nominal
  • MSC General Purpose Inputs and Output:
    • Inputs: 2 GPI inputs connected to both Master A and Master B through AUX I/O
    • Outputs: 2 GPI outputs connected from
    • Master A through AUXI/O A
    • 2 GPI outputs connected from Master B through AUXI/O B
    • Connector: 6 pins on 12–pin removable terminal block
    • Signal Level: As specified in 5700MSC manual
  • 10 00BASE–T Control Network:
    • Quantity: 1
    • Network Type: IEEE 802.3 (10BASE–T)
    • IEEE 802.3u (100BASE–TX)
    • IEEE 802.3ab (1000BASE–T)
  • Changeover conditions:
    • Changeover is a voting system based on which source has the most good signals and that the good signals on the current master are also present on the backup master. The input signals are considered good according to the following criteria:
  • Video: Level below 70 IRE
  • Sync: H timing detect
  • 10MHz: 3dB level below 0.3V p–p
  • DARS: Sync word error
  • LTC: Level below 0.3V p–p
  • Incorrect sync word
  • Electrical:
    • Power: Auto ranging 100–240V AC, 50/60Hz, 40W
    • Configuration: Dual redundant supplies
    • Fuse Rating: 250V, 1 amp, time delay
    • Safety: TüV Listed
    • Complies with EU safety directives
    • EMI/RFI: Complies with FCC Part 15 Class A
    • Complies with EU EMC Directive
  • Physical:
    • Dimensions: 19" W x 3.5" H x 11.5" D
      • (483mm W x 90mm H x 292mm D)
    • Weight: 16lbs (3.5kg)

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Product Documents

Click to download