SurgeX SA-82-AR 3 Outlet Power Conditioner and Surge Protector, IP Enabled

OUR PART #: SA-82-AR MFR #: SURSA82AR

Copied to clipboard

The SA-82-AR provides guaranteed surge protection and power conditioning for audio, video, broadcast and computer equipment. ...Read more

SurgeX SA-82-AR 3 Outlet Power Conditioner And Surge Protector, IP Enabled Image 1
SurgeX SA-82-AR 3 Outlet Power Conditioner And Surge Protector, IP Enabled
Our Price: $859.00

SPECIAL FINANCING AVAILABLE

Synchrony Music & Sound Card
$24/mo* with 36 month financing. ‡
Limited Time. Learn How
Item usually available to ship in 5-9 Business Days. Please call for up-to-date information on product availability.

Questions? Contact our
Sales and Service Pros for expert
advice and package pricing.

800-356-5844

Email customer service

Accessories

Product Overview

The SA-82-AR provides guaranteed surge protection and power conditioning for audio, video, broadcast and computer equipment. The units are 8-amp load-capable and have 2 industrial grade grounded AC receptacles.

The SA-82-AR utilizes our patented Series Mode® surge protection technology, Impedance Tolerant® EMI/RFI filtering and Over-Voltage-Shutdown which automatically restores power when line voltage returns to a safe level. The unit’s compact design can be easily integrated with today’s Flat Panel monitor mounting systems. The FlatPak™ SA-82-AR comes with a detachable IEC power cord and universal mounting brackets.

The SA-82-AR shall be a compact mountable unit in a magnetic shielding steel enclosure. It shall operate from 120 volts AC and include a separate 3-foot, grounded, 3-wire #18 line cord. There shall be 2 grounded AC receptacles. Overall dimensions shall be 1.75" H x 5.31" W x 9.06" D. Weight shall be 3.4 pounds.

The SA-82-AR shall have a load rating of 8 amps @ 120 volts. It shall be listed to UL 1449-2 and certified to Federal Grade A, Class 1, Mode 1 Guidelines for powerline surge suppressors. The unit shall provide auto-resetting overvoltage shutdown. There shall be three limiter circuits: a series surge reactor current limiter, a cascaded auto-tracking dual-polarity voltage limiter, and a pulse inverter. The onset clamping voltage shall be 172 volts nominal, and the unit shall have an instant-reacting snubber to protect against fast-rising surges generated within the installation location. The surge suppressor shall have an unlimited Applied Surge Current rating (8 x 20 µs) and shall withstand at least 1000 occurrences of Surge Pulse Voltages up to 6000 volts.

Features:

  • Magnetic shielding steel enclosure
  • 3’ grounded 3-wire #18 line cord (separate)
  • 2 grounded AC receptacles
  • Series Mode surge protection
  • Auto-resetting Overvoltage shutdown
  • Thermal circuit breaker overload protection
  • Self-test circuit with visual indicator
  • Made in U.S.A.

Specifications:

  • Load Rating: 8 amps @ 120 volts
  • Power Requirement (no load):10 watts
  • UL 1449-2 Adjunct Classification Test Results
    • 1000 surges, 6000 volts, 3000 amps,
    • C1 pulse, measured suppressed voltage 290 volts, no failures
  • Federal Guidelines:
    • Grade A, Class 1, Mode 1 (CID A-A-55818)
  • EMI/RFI Filter, Normal Mode (50-ohm load):
    • 40 dB @ 100 kHz; 50 dB @ 300 kHz;
    • 50 dB @ 3 MHz; 50 dB @ 30 MHz
  • EMI/RFI Filter, Common Mode (50-ohm load):
    • 18 dB @ 300 kHz; 30 dB @ 1 MHz;
    • 50 dB @ 5 MHz; 50 dB @ 20 MHz
  • Maximum Applied Surge Pulse Joule Rating:
    • Unlimited, due to current limiting (8 x 20 µs)
  • Maximum Applied Surge Pulse Voltage:
    • 6000 volts (1.2 x 50 µs pulse), industry standard rating
  • Maximum Applied Surge Pulse Current:
    • Unlimited, due to current limiting (8 x 20 µs)*
  • Endurance: IEEE C62.41-1991 Category B3 (C1)
  • Pulses: 1 kv>500,000; 3 kv>10,000; 6 kv>1000
  • Overvoltage Shutdown: 145 volts (resume at 135 volts)
  • Dimensions: 1.75" H x 5.31" W x 9.06" D
  • Weight: 3.4 lbs
  • Temperature Range: 5º to 35º C
  • Humidity Range: 5% to 95% R.H., non-condensing
  • Agency Listings: ETL and cETL (UL 1449, 2nd edition;
    • CSA C22.2 No.8-M1986, R2000)

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.