Roland Professional A/V S4000S-0832 8x32 Digital Snake Modular Stagebox

OUR PART #: S4000S-0832

Copied to clipboard

40 Channel I/O modular rack configured to be used at the Front of House position for connection to mixing console with ordinary XLR cables. ...Read more

Roland Professional A/V S4000S-0832 8x32 Digital Snake Modular Stagebox Image 1
Roland Professional A/V S4000S-0832 8x32 Digital Snake Modular Stagebox
No longer available at Full Compass
We've left this page up for reference only.

Questions? Contact our
Sales and Service Pros for expert
advice and package pricing.

800-356-5844

Email customer service

Product Overview

40 Channel I/O modular rack configured to be used at the Front of House position for connection to mixing console with ordinary XLR cables. The configuration would be used with an S-4000S-3208 at the stage position. 8 input + 32 output.

The S-4000S-0832 is a component of the S-4000 Digital Snake System. It has 8 inputs, 8 outputs and redundant Ethernet connectors. It is typically used on the stage providing 8 mic/line inputs and 32 outputs or returns. Each channel has remotely switchable Phantom Power as well as a 20dB pad. The professional quality XR-1 mic preamps are remotely controllable in zipperless 1dB steps using the S-4000R Remote Controller or a Mac or PC using the free RCS software. The preamps have been designed for live sound applications and provide superb audio quality with 28dB of headroom.

Features:

  • 8 Mic/Line Inputs and 32 +4 Line Level Outputs provide professional quality source and return audio
  • Source audio can be split to many locations using a standard Ethernet gigabit Switch
  • High quality XR-1 mic preamps provide superb sound with lots of headroom
  • Zipperless remote control of preamp levels available using S-4000R from stage or FOH positions
  • Mic preamps on stage and digital audio transmission system eliminate the loss of high frequencies and intelligibility found in analog cabling
  • Mic/Line level eliminates need for direct boxes on stage
  • Redundant Ethernet ports with rugged Neutrik Ethercon connectors offer seamless switching to backup cable with no loss of audio
  • Optional S-240P power supply switches automatically with no loss of audio in case of power supply interruption
  • Modular design allows Input and Output modules to be changed for different system configurations

Specifications:

  • Number of Channels:
    • 8 in, 32 out
  • AD Conversion:
    • Sample Rate: 96.0kHz
    • Signal Processing: 24-bit
  • DA Conversion:
    • Sample Rate: 96.0kHz
    • Signal Processing: 24-bit
  • Frequency Response:
    • -2dB / +0dB (@ +4dBu, 20Hz - 20kHz)
  • Total Harmonic Distortion + Noise:
    • 0.05% or less (Pad: On, Input Gain: +4dBu, 22 - 20000Hz)
  • Dynamic Range:
    • 110dB
  • Cross Talk:
    • -80dB
  • Nominal Input Level:
    • -65 to -10dBu (PAD: Off) -45 to +10dBu (PAD: On) (1dB step, Max. +28dBu)
  • PAD:
    • 20dB On/Off
  • Input Impedance:
    • 20kΩ
  • Nominal Output Level:
    • +4dBu, Max. +22dBu
  • Output Impedance:
    • 150Ω
  • Recommended Load Impedance:
    • 10kΩ or greater
  • Residual Noise Level (IHF-A, typ.):
    • -90dBu
  • Equivalent Input Noise Level (E.I.N.):
    • -128dB
  • Network Latency:
    • 375 microseconds when using REAC cable only (AD - REAC - DA Latency: about 1.2ms)
  • Connectors:
    • Input: 8 (XLR type, balanced, phantom power, 4 ch input module x 2 )
    • Output: 32 (XLR type, balanced, 4 ch output module x 8)
    • REAC: MAIN, BACKUP (RJ-45 EtherCon type)
    • Remote Connector: 1 (RS-232C,DB-9 type)
    • MIDI Connectors: IN, OUT (5-pin DIN type)
  • Indicator:
    • EXT Indicator (External Power Supply Unit)
    • INT Indicator
    • REAC Indicator
    • CTRL Indicator
    • ALARM Indicator
    • MUTE ALL OUTPUTS Indicator
  • AC Power Supply:
    • AC115V, AC117V, AC220V, AC230V, AC240V (50 / 60Hz)
  • DC Power Supply:
    • +24V (from optional external power supply unit : S-240P)
  • Phantom Power:
    • +48V / 14mA (each input on SI-AD4, remote controlled)
  • Operation Temperature:
    • 0 to +40 degrees Celsius +32 to +104 degrees Fahrenheit

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Product Documents

Click to download