Tripp Lite IS1000HG Isolator Series Medical Grade Transformer, 4 Hospital Grade Outlets, 1000W

OUR PART #: IS1000HG MFR #: IS1000HG

Copied to clipboard

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. ...Read more

Tripp Lite IS1000HG Isolator Series Medical Grade Transformer, 4 Hospital Grade Outlets, 1000W Image 1
Tripp Lite IS1000HG Isolator Series Medical Grade Transformer, 4 Hospital Grade Outlets, 1000W
Our Price: $600.96
List Price: $796.00
You save 25%!
Synchrony Music & Sound Card
No Interest if paid in full within 6 Months
Learn How
Item usually available to ship in 9-12 Business Days. Please call for up-to-date information on product availability.

Questions? Contact our
Sales and Service Pros for expert
advice and package pricing.

800-356-5844

Email customer service

Accessories

Product Overview

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1000HG includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit housing; ships ready for placement in any industrial, medical, office or network environment. 2-year warranty.

PLUG/OUTLETS: Input—NEMA 5-15P Hospital Grade; Output—4 NEMA 5-15R Hospital Grade

ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle)

FORMAT: Upright tower

ISOLATION: Transformer-based line isolation with Faraday shield

Features:

  • The IS1000HG Medical Grade Isolation Transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression
  • Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas
  • Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps
  • Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
  • Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
  • Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops
  • Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
  • Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Includes 4 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch
  • Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
  • 2-year limited product warranty

Specifications:

  • Amp Capacity: 8.3A at 120V AC
  • Efficiency: 96%
  • Form Factor: Small tower format
  • Input Plug: Type NEMA 5-15P-HG Hospital-Grade
  • Leakage Current: Less than 100 microamps
  • Let-through Voltage (Combination Wave): L-N: 250V L-G: 250V N-G: 0.5V
  • Let-through Voltage (Ring Wave): L-N: 20V L-G: 20V N-G: 0.5V
  • Noise Suppression Rating: 35-65 DB
  • Nominal Voltage / Frequency: 120V / 60Hz
  • Output Receptacle Qty / Type: 4 NEMA 5-15R-HG Hospital-Grade
  • Over Current Protection: 9.0A circuit breaker
  • Shipping Weight: 58.00 lbs /26.31 kg
  • Suppression Joule Rating: 680 (510 input/170 output)
  • Surge Test Conditions: Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms
  • Total Harmonic Distortion: Less than 1%
  • Transformer Type: Medical-grade, low impedance transformer-based line isolation transformer
  • Unit Dimensions (HWD/in.): 7.75 x 7.25 x 10.5
  • VA / Watt Capacity: 1000
  • Warranty: 2-year limited product warranty
  • INPUT
    • Input cord length (ft.): 6 ft.
  • PHYSICAL
    • Cooling method: Convection

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.