Specifications:

  • Display: 4-digit via 7-segment LEDs
  • Connectors: 1/4" TSR phone jack
  • Power Requirements: 115Vac @ 60Hz
  • Approvals:
    -
    Emissions: - EN 55022 B - FCC Class B
    -
    Immunity: - EN 55024 B
  • Size:7-7/8" W x 2-5/8" H x 7" D
  • Weight: 2 lbs.
  • Case Material: High impact ABS
  • Front & Rear Panels: Painted aluminum

The Low Distortion Oscillator:
A current controlled, state-variable true sine wave oscillator incorporating a fast AGC circuit.  Distortion components are typically 0.1% 2nd and 0.05% 3rd which are low order and not audible making the TS2 useful in making listening tests where a function generator would generate undesirable, audible side effects.  Full frequency sweeps can be made from 20Hz - 20kHz in a single range. These units have no amplitude changes over the entire frequency range.
 

  • Frequency range:
    - 10Hz - 30kHz
  • Accuracy: ± 0.1dB from 20Hz - 20kHz.
  • Output impedance: 50 ohm unbalanced. Optional balanced available.
  • Adjustable output level: -70dBv to +18dBv ref: (0.775V)
  • Maximum output level: +18dBv @ 2k ohm or greater, +16.5dBm @ 600 ohms.
  • Distortion: < 0.3% THD

The Frequency Counter:
The frequency counter is internally connected to the internal oscillator and displays the oscillator frequency until a signal is plugged into the input connector. It then displays the frequency of the input signal. 
The frequency counter is disabled below 40dB to avoid induced count errors. Below 10KHz the counter updates mice a second. Above 10KHz it updates ten times per second. This unique combination of Frequency Counter and Audio Oscillator affords absolute precision in setting frequencies.

  • Frequency response: 1Hz-99.99kHz
  • Input impedance: >100k ohms (electronically balanced).
  • Input level: -40dBv to +24dBv ref: (0.775V)

The dB Meter:
The dB meter is a wideband average responding AC voltmeter. The circuit output is electronically converted to dB for display. Direct reading dB greatly simplifies alignment procedures. 
The logarithmic nature of decibels eliminate the need for range switches.  A reference level of "0dB" is factory set for 0.775v which can be user adjusted +10dB with a rear panel control.

  • Meter Range: -50dBv to +24dBv ref: (0.775V)
  • Accuracy:
    - ±0.1dB from 20Hz - 20kHz @ 0dBv
    - ±1.5dB from 20Hz -20kHz @ 50dBv
  • Adjustable zero reference: -10dBv to +8dBv (rear panel adjustment)

The Impedance Meter

The TS-2 incorporates a compact impedance measuring instrument which, will determine impedances (Z) in the audio frequency range.  The TS-2 will read impedances from I ohm to 1000 ohms (versions are available from 1 ohm to 10K ohms), and will read them at frequencies from 20Hz to 27KHz.  The TS-2 features a continuously variable sine wave generator that can be tuned in any audio frequency and fed thru a known resistance and into the unknown impedance to be measured.  Precision AC to DC, converters measure the magnitude of the current supplied and the voltage across the unknown impedance.  To read impedance the user simply sets the frequency he requires, attaches the load to be read to the output of the oscillator, and depresses the switch marked Z.  To plot a curve he simply repeats the procedure at the frequencies in question.  The TS-2 has a balanced input and an unbalanced output addressed via 1/4" connectors.  An overrange LED is provided when reading impedances above either 1K or 10K depending on the model.  A maximum, measuring error of less than 50A is typical.

Battery Specifications:

  • Volts: 12Vdc (Nominal)
  • Capacity (@ 20 hr. rate): 1.2 A.H.(Nominal)
  • Discharge Current (@ 20 Hr rate):
  • Operation:
    Unit ACpower ON, Battery power OFF - battery inoperative, see recharging.
    Unit ACpower ON, Battery power ON - battery in standby, will operate in the event ofAC power failure.
    Unit AC power OFF, Battery power ON - batteryis powering unit.
  • Recharging: Battery is automatically recharged whenever the unit is plugged into AC power and the AC power switch is ON.  Recommended that battery switch is in the OFF position.
  • Size: 4" W x 2" H x2" D
  • Weight: 1.4lbs.
  • Case Material: Mill Finish Aluminum

Our Part #  TS2-BP

FROM OUR CUSTOMERS
Featured Offers

HACKER SAFE certified sites prevent over 99.9% of hacker crime.

Secured by Thawte

Full Compass is an Upfront Merchant on TheFind. Click for info.

Copyright © 2012 Full Compass Systems, LTD. All rights reserved.
Please read our Terms of Service, Privacy Policy and Conditions Statement.
Not responsible for typographical errors in pricing or product specification inaccuracies in our catalog or web site. Prices are subject to change without notice.

Proud Member of:
Logo: AES Click to verify BBB accreditation and to see a BBB report. Logo: GSA Advantage Logo: National Association of Broadcasters Logo: NSCA Logo: Society of Broadcast Engineers
Logo: InfoCOMM Logo: NAMM
Full Compass is a national leader in Professional Audio, Professional Video, A/V and Lighting sales. For over 30 years, our goal has been to provide the best possible value with exceptional customer service. We offer over 700 top equipment brands including, Shure, Yamaha, Panasonic, Sony, JBL, Sennheiser, Sanyo, QSC, Audio-Technica, Crown and much more. We also provide services such as computer systems integration, lighting design, and rentals. Full Compass is an authorized service center and parts distributor for most of the major manufacturers we carry.