(0)

Questions? Call Us:
800-356-5844

American Power Conversion SMX3000RMLV2UNC
Smart UPS X 3000VA, with Network Card

OUR PART #:  SMX3000RMLV2UNC

The APC® by Schneider Electric Smart-UPS® X is a high performance uninterruptible power supply (UPS).
Learn More
Our Price: $1,846.58
List Price: $2,620.00
You save 30%!
Write the first review.

We guarantee to match pricing on the products we sell for new, identical and immediately available products if you see them offered at a lower price. Please contact us if you find a lower price before purchasing.

Learn More

Low Price

Guaranteed

American Power Conversion SMX3000RMLV2UNC
Qty:
Usually ships in 7-14 business days.
Need it sooner? Call us!

Similar Products

The APC® by Schneider Electric Smart-UPS® X is a high performance uninterruptible power supply (UPS). It provides protection for electronic equipment from utility power blackouts, brownouts, sags, and surges; small utility fluctuations and large disturbances. The UPS also provides battery backup power until utility power returns to safe levels or the batteries are fully discharged.

Features:

  • Intuitive LCD interface: Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
  • High frequency design: Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
  • Auto recognition of external batteries: UPS recognizes when external battery packs are attached and automatically adjusts runtime.
  • Predictive replace battery date: Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
  • Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Energy meter: Provides actual kilowatt hours of usage for energy conscious users.
  • Outlet group control: Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
  • Sequenced shutdown and restart: Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).
  • Load shedding: Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).
  • Pure sine wave output on battery: Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
  • Multiple switched outlet groups: Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
  • Wide input voltage range: Designed for harsh electrical environments to save battery life.
  • StruxureWare Central compatible: Enables centralized management via StruxureWare Central.
  • Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • High online efficiency: Reduces utlility costs, generates less heat.
  • LED Indicators: Provide easy-to-read status of the unit and utility power conditions.
  • Overload protection: Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
  • SmartSlot: Customize UPS capabilities with management cards.
  • Cold-start capable: Provides temporary battery power when the utility power is out.
  • Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Disconnected battery notification: Warns when a battery is not available to provide backup power.
  • Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
  • Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Audible alarms: Provides notification of changing utility power and UPS conditions
  • User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • USB connectivity: Provides management of the UPS via a USB port (not available on all models).
  • Serial Connectivity: Provides management of the UPS via a serial port.
  • Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
  • Scalable runtime: Allows additional run time to be quickly added as needed.
  • Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Rack/Tower convertible: Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Network manageable: Provides remote management of the UPS over the network.
  • Frequency and voltage regulation: Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Predicitive failure notification: Provides early-warning fault analysis ensuring proactive component replacement.
  • Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
  • Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
  • Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Disconnected battery notification: Warns when a battery is not available to provide backup power.
  • Network manageable: Provides remote management of the UPS over the network.
  • Audible alarms: Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
  • LED status indicators: Quickly understand unit and power status with visual indicators.
  • Serial Connectivity: Provides management of the UPS via a serial port.
  • USB connectivity: Provides management of the UPS via a USB port (not available on all models).
  • Disconnected battery notification: Warns when a battery is not available to provide backup power.
  • User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Predictive failure notification: Provides early-warning fault analysis ensuring proactive component replacement.
  • Resettable circuit breakers: Enables a quick recovery from overload events.
  • Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Specifications:

Output

  • Output Power Capacity: 2700 Watts / 3000 VA
  • Max Configurable Power: 2700 Watts / 3000 VA
  • Nominal Output Voltage: 120V
  • Output Voltage Distortion: Less than 5% at full load
  • Output Frequency (sync to mains):
      -  47 - 53 Hz for 50 Hz nominal
      -  57 - 63 Hz for 60 Hz nominal
  • Topology: Line Interactive
  • Waveform Type: Sine wave
  • Output Connections:
      -  (3) NEMA 5-15R
      -  (3) NEMA 5-20R
      -  (1) NEMA L5-30R

Input

  • Nominal Input Voltage: 120V
  • Input Frequency: 50/60 Hz +/- 3 Hz (auto sensing)
  • Input Connections: NEMA L5-30P
  • Cord Length: 8 feet (2.44 meters)
  • Input voltage range for main operations: 70 - 153V
  • Transfer Time: 2-4 ms

Batteries & Runtime

  • Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Typical recharge time: 3 hour(s)
  • Replacement Battery: APCRBC117 
  • RBC™ Quantity: 1

Communications & Management

  • Interface Port(s): SmartSlot
  • Pre-Installed SmartSlot™ Cards: AP9631 
  • Control panel:
      -  LED status display with On Line : On Battery : Replace Battery and Overload indicators
      -  Multi-function LCD status and control console
  • Audible Alarm: Alarm when on battery : distinctive low battery alarm : configurable delays
  • Emergency Power Off (EPO): Yes

Surge Protection and Filtering

  • Surge energy rating: 540 Joules
  • Filtering: Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
  • Data Line Protection: --

Physical

  • Maximum Height: 3.36 inches (85 mm)
  • Maximum Width: 17.00 inches (432 mm)
  • Maximum Depth: 26.26 inches (667 mm)
  • Rack Height: 2U
  • Net Weight: 84.60 lbs. (38.45 kg)
  • Shipping Weight: 99.79 lbs. (45.36 kg)
  • Shipping Height: 9.58 inches (243 mm)
  • Shipping Width: 23.48 inches (596 mm)
  • Shipping Depth: 34.23 inches (869 mm)
  • Color: Black

Environmental

  • Operating Environment: 32 - 104 °F (0 - 40 °C)
  • Operating Relative Humidity: 0 - 95%
  • Operating Elevation: 0-10000 feet (0-3000 meters)
  • Storage Temperature: 5 - 113 °F (-15 - 45 °C)
  • Storage Relative Humidity: 0 - 95%
  • Storage Elevation: 0-50000 feet (0-15000 meters)
  • Audible noise at 1 meter from surface of unit: 55.00 dBA
  • Online Thermal Dissipation: 276.00 BTU/hr

Conformance

  • Regulatory Approvals: BSMI, CSA, EN 50091-2, EN 55022 Class A, FCC Part 15 Class A, NOM, TUV, UL 1778, VCCI Class A
  • Standard Warranty: 3 years repair or replace (excluding battery) and 2 year for battery, optional extended warranties available, optional on-site warranties available
  • Equipment protection policy: Lifetime : $150000

Sustainable Offer Status

  • RoHS: Compliant
  • REACH: REACH: Contains No SVHCs

What's Included:

  • CD with software
  • Documentation CD
  • Installation guide
  • Rack Mounting brackets
  • Rack mounting hardware
  • Rack Mounting support rails
  • Removable support feet
  • Smart UPS signalling RS-232 cable
  • USB cable
  • Web/SNMP Management Card

To be the first to review this item, click here.

Add to Cart

We're sorry, only of this item available



Call a Sales Pro at 800-356-5844 for more information

© 2017 Full Compass Systems, LTD  9770 Silicon Prairie Parkway, Madison, WI 53593  All rights reserved.

We are not responsible for typographical errors in pricing or product specification
inaccuracies in our catalog or web site. Prices are subject to change without notice.