Product Overview
The XCC XLR cable connector Series with circumferential shield contact provides excellent RF-protection to transmit digital audio signals most efficient and reliable. This XLR features a coaxial ground spring and a coaxial hex crimp ferrule at the cable entrance for proper and reliable transition of the shield to the shell.
3 pole male cable connector, RF-protected, gold contacts
Cable O.D.: 5.4 - 6.2 mm
Crimp Size Shield: 6.5 mm (hex)
Features:
- 3 pole cable connector with a circumferential shield contact for best EMI protection
- XCCR coding ring to indicate digital AES signals included
- Rugged zinc diecast shell, long lasting and durable
- Chuck type strain relief system for secure clamping of cables
- Boot with rubber gland gives high protection against bending stresses
Specifications:
- Electrical Specifications:
- Capacitance between contacts: = 4 pF
- Contact resistance: = 3 m ohm
- Dielectric strength: 1,5 kVdc
- Insulation resistance: > 2 G ohm (initial)
- Insulation resistance: > 1 G ohm (after damp heat test)
- Rated current per contact: 16 A
- Rated voltage: 50 V
- Shielding effectiveness: > 55 dB @ 1.3 GHz
- Mechanical Specifications:
- Cable O.D.: 5.4 - 6.2 mm
- Crimp size: 6,47 Hex crimp (shield) acc. IEC 60803 (die designation E)
- Insertion force: = 20 N
- Withdrawal force: = 20 N
- Lifetime: > 1000 mating cycles
- Wire size: max. 2.5 mm²
- Wire size: max. 14 AWG
- Wiring: Solder contacts
- Locking device: latch lock
- Crimp tool: "6.5 mm Hex die (size "
- Material Specificaitons:
- Boot: E" acc. To IEC 60803)"
- Bushing: Polyuretan
- Cap / Nut / Washer: Polyamide (PA6 15% GR)
- Contact plating: PA 6 15% GR
- Contacts: 0.2 µm Au hard alloy over 2 µm Ni
- Contacts: Brass (CuZn39Pb3)
- Insert: CuZn39Pb3, Ni plated
- Locking element: Polyamide (PA 6.6 30 % GR)
- Gasket: St3K32 (latch) / Ck 67 (spring)
- Shell: Zinc diecast (ZnAl4Cu1)
- Split sleeve: Nickel
- Color coding: Polyacetal (POM)
- Circumferential ground spring: CuSn6, Ni plated
- Environmental Specifications:
- Flammability: UL
- Standard comppliance: UL 94 HB
- Savety requirements: IP 40
- Temperature range: Complies with IEC 68-2-20 °C
- Optical Fiber type: Manufacturing Standard IEC 61076-2-103