SurgeX SA-15 Power Conditioner, 15 Amps, 120 Volts

OUR PART #: SA15 MFR #: SURSA15

Copied to clipboard

The SA-15 and SA-20 are specifically designed to upgrade and improve surge protection for audio, video, computer and all sensitive electronic equipment. ...Read more

SurgeX SA-15 Power Conditioner, 15 Amps, 120 Volts Image 1
SurgeX SA-15 Power Conditioner, 15 Amps, 120 Volts
Our Price: $629.00

SPECIAL FINANCING AVAILABLE

Synchrony Music & Sound Card
$18/mo* with 36 month financing. ‡
Limited Time. Learn How
Item usually available to ship in 9-12 Business Days. Please call for up-to-date information on product availability.

Questions? Contact our
Sales and Service Pros for expert
advice and package pricing.

800-356-5844

Email customer service

Accessories

Product Overview

The SA-15 and SA-20 are specifically designed to upgrade and improve surge protection for audio, video, computer and all sensitive electronic equipment. These standalone units when fitted with optional mounting brackets easily mount where you need them. The SA-15 rated for 15 amps and the SA-20 rated for 20 amps both feature two industrial grade grounded AC receptacles and feature Impedance Tolerant® EMI/RFI filters. SurgeX patented advanced Series Mode Pro™ technology is superior to conventional MOV circuitry. Both units provide proven, reliable protection: blocking and containing surges of up to 6,000 volts, unlimited current, without noise producing ground contamination. The SA-15 and SA-20 meet the most stringent government purchase specifications for AC powerline surge suppressors. The A-1-1 rating assures you of dependable protection from destructive spikes, surges and inductive transients.

Features:

  • Made in U.S.A., Listed to UL 1449-2
  • Magnetic shielding steel enclosure
  • 9’ grounded 3-wire #14 line cord
  • Two grounded receptacles on top panel: unswitched
  • Self-test circuit with visual indicator
  • Dimensions (W x H x D): 10.22" x 4.0" x 4.2" (26.0 x10.6 x 10.7 cm)
  • Weight: SA-15: 8.0 lbs. (3.6 kg)

Specifications:

  • Load Rating: SA-15 - 15 amps @ 120 volts
  • UL 1449-2 Adjunct Classification Test Results: 1000surges, 6000 volts, 3000 amps, C1 pulse, measured suppressed voltage 290volts, no failures.
  • 1996 Federal Guidelines, Grade A, Class 1, Mode 1:Both models meet guidelines. Limiters (3 circuits): Series surge reactor current limiter. Cascaded autotracking dual polarity voltage limiter. Dualpulse inverters.
  • Clamping Voltage Onset: 172 volts nominal (2 voltsabove peak line voltage, auto-tracking).
  • Filter (bi-directional, wave tracking): With 50 ohmload: 3 dB @ 3 kHz; 38 dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 5 MHz; 50 dB @30 MHz.
  • Let-Through Slew Rate: 5000 volt/µs disturbance reduced to 28 volt/µs within power wave envelope; less than 10 volt/µs outside power wave envelope.
  • Snubber: Instant-reacting snubber for fast-rising surges generated within the building.
  • Maximum Applied Surge Pulse Joule Rating: Unlimited,due to current limiting (8 x 20 µs).
  • Maximum Applied Surge Pulse Voltage: 6000 volts (1.2x 50 µs pulse), industry standard rating.
  • Maximum Applied Surge Pulse Current: 100,000 amperes (8 x 20 µs).Endurance: IEEE C62.41-1991 Category B3 (C1) Pulses: 1 kv>500,000; 3kv>10,000; 6 kv>1000 (NRTL-UL certified).

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.